2020 Atlas Copco QAS Generators 70 ID
- Year 2020
- Make Atlas Copco
- Model QAS Generators
- Engine Model: Isuzu 4JJ1X
2020 Atlas Copco QAS Generators 70 ID
Mobile diesel generatorsThe QAS range, from 25 to 625 kVA
Features may include:
Up to 20 MVA stable power- 32 units of the QAS 625 can be linked together in paralleling for specialized applications, providing up to 20MVA of stable and reliable power.
- 1000 hour salt test
- Up to 40-hour fuel tank capacity provides longer runtime between fill ups and optimum site autonomy.
- The starting mechanism ensures that stable power is achieved in less than six seconds.
- All QAS generators include the latest Tier 4 Final engine
- All QAS generators have dual stage filtration with a safety cartridge and dual stage air cleaning. This centrifugal dust separation system and heavy duty filtration system prolongs the life of your generator.
- The ideal mobile diesel generator solution for rental companies
- The QAS generator range was designed specifically for the needs of the US market. The range has been completely overhauled and incorporates nine models covering power rating from 25 to 625 kVA. All QAS generators include the latest Tier 4 Final engine and have a footprint that is up to 20 per cent smaller than the previous generation. The starting mechanism ensures that stable power is achieved in less than six seconds.
- The range is all about the user experience and maintaining the value of your asset. It’s packed with features that make operating, transporting and maintenance as easy as possible.
- What is more, up to 32 units of the QAS 625 can be linked together in paralleling for specialized applications, providing up to 20MVA of stable and reliable power.
- When you need power, maybe a single generator is not always the most efficient solution. Does the application load vary? Do you need prime power for long term projects on a remote site? Do you need a semi-permanent installation that can be upgraded or downgraded?
- A Modular Power Plant (or paralleling multiple generators) is the efficient solution if you answered yes to any of the above questions. Simply, this is a configuration of generators working together.
- We have developed a unique Power Management System (PMS). The PMS system enables the optimization of fuel consumption and expands the generator’s lifetime. PMS manages the quantity of generators running in parallel with load demand, starting and stopping units in line with increases or decreases in load. In this way, the load on each generator remains at a level which optimizes fuel consumption. It also eliminates the need for generators to run with low load levels, which can cause engine damage and shorten the life expectancy of the equipment.
- The generators incorporate Atlas Copco’s Power Management System (PMS) that manages the quantity of generators running in parallel with load demand, starting and stopping units in line with increases or decreases in load. In this way, the load on each generator remains at a level which optimizes fuel consumption and eliminates the need to run with low load levels, which can cause engine damage and shorten the life expectancy of the equipment.
Engine
Engine
Model: Isuzu 4JJ1X
Engine Power
Continuous Output: 88 hp (65.5 kW) | Gross Output: 95 hp (71 kW)
Rated Engine Speed
1800 rpm
Displacement
2.99 L
Cylinder Liners
4
Aspiration
Turbo w/Intercooler
Emissions
US EPA Family: HSZXL03.0RXB | US EPA Tier: Tier 4 Final
Battery
Battery Capacity, Maximum
1100 A
Electric
Electrical
Frequency: 60 Hz | Rated prime power 3ø: 56 kW (70 kVA) / Standby: 60 kW (75 kVA) | 3ø Voltage in 480V switch position (series star w/neutral): 480Y / 277 V | Amp capacity @480V: 90 A | 3ø Voltage in 240-208V switch position (parallel star w/neutral): 240YY / 139 - 208YY V | Automatic voltage regulator (+/-0.5%): Leroy Somer R438 | Electrical system (Negative ground): 12 V | Amp capacity @240V: 180 A / 130 A | Amp capacity @208V: 180 A | 1ø Voltage in 120-240V switch position (Zig-Zag): 240 / 120 V | Amp Capacity @120V: 130 x2 A | Main breaker - Shunt trip: 200 A | 3ø Power factor: 0.8 | 1ø Power factor: 1.0 | Rated prime power 1ø: 39 kW (39 kVA)
Alternator
Leroy Somer 42.3 L9 | Engine output: 110 A
Operational
Operating Conditions
Fuel consumption at full load (PRP): 3.95 gal/h (15.0 l/h) | Fuel autonomy at full load and 90% of fuel capacity: 25.1 h
Operating Temperature, Maximum
Ambient (@Sea Level): 122 ºF (50 ºC) | Min. starting: 14 ºF (-10 ºC)
Performance
Noise Level
Max. sound pressure (LPA) @23' @75% Load: 67 dB(A)
Dimensions
Length
Skid: 93 in | w/ Trailer: 143 in
Width
Skid: 41 in | w/ Trailer: 65 in
Height
Skid: 56 in | w/ Trailer: 75 in
Capacities
Fuel Capacity
Tank: 110 gal (416 l)
Features
Fuel autonomy considering 90% of fuel capacity: 40.3 h
Oil capacity
Engine: 3.7 gal (14 L)
Cooling System
Engine: 1.6 gal (6 L)
Weights
Weight
Skid wet: 4047 lbs | w/ Trailer wet: 4527 lbs
Features
Features
Excitation: AREP | Insulation: Class H | Power distribution - Terminal board: 5 Wire (L1, L2, L3, N, Ground) | Terminal board connections: Bare wire Terminals | Maximum terminal cable size: 350 MCM | Convenience receptacles: 2 x NEMA 5-20R & 2 x 125/250V 50A CS6364